RAID 5 arrays are used for many applications because they are inexpensive for the most part and a level of fault tolerance has not been made by a different RAID levels available. As with any RAID level, RAID 5 can be many different types of problems. This article is brief discussion of some of the problems caused as a RAID 5 failure and data recovery can work to solve these problems.

Problems that the RAID 5 can causeFailure

Bad Sectors

A RAID 5 can fail due to bad sectors on one disk in the array. This may force the array to go offline.

Corrupt data

A RAID 5 can suffer Platter to corrupt data due to many reasons, including viruses, user errors, overwriting files and scratches on the surface of the disk.

Degraded RAID 5

A RAID-5 is degraded when there is a loss of one of theMember disks. This leads to a huge decrease in performance and also eliminated the fault tolerance of RAID-5. The operation of a degraded RAID 5 is dangerous, because the loss of a second hard disk will cause the entire array is lost.

Deleted files

Many times a user to accidentally delete important data in a RAID 5 array. Other times, it is done deliberately by disgruntled employees. In most situations, deleted files are restored.

MissingPartitions

In many cases, the partition table is damaged or missing to disappear as an entire partition or unusable. This makes data recovery is necessary. The test software will rest with the risk of permanent data loss.

RAID 5 Controller Failure

A hardware RAID 5 array uses a control that contains all of the logic and provides for the operations of the array. For many reasons, the arrayexperience a controller failure. This can cause the array does not start up. It could also cause to disappear the logical volume.

RAID 5 Disk Failure / RAID 5 Drive Failure

A RAID-5 is a set of three or more disks. Each of these drives do fail. A RAID-5 is the ability to fail only one disk at a time withstand configured. In most cases, the RAID can be written in recovering a data recovery lab with parity datathe discs through the array. Even if more than one drive has failed, recovery is still possible in a lab data recovery.

RAID 5 Firmware Failure

Firmware problems can occur in the RAID controller or the member disks.

RAID 5 Rebuild Failure

For various reasons, a RAID 5 array experience a rebuild failure. This can keep offline member disks and make the array unusable.

ServerCrash

Often experienced by the host server problems and may crash. This of course makes the array inaccessible. A data recovery lab can restore the data from the member drives.

How to make sure RAID 5 data recovery is successful

If you have experienced a RAID-5 failure, it is important that you do not take matters into their own hands. This allows the parity data is overwritten. Parity datathe plates written to the Member, in many cases crucial for a successful recovery. The very first thing you should what is off the RAID server immediately to ensure that no additional writes performed. All events describe what may have happened to cause the problem should be noted. If the member drives will be removed from the server, they should be in the correct order they were removed to be labeled. The disk is very important for when the time factor. This isalso important if you have a large number of partitions.

In order to increase a successful data recovery, it is important that the failed RAID remain intact fifth Find more information related recreation, be 5 by RAID.